The SGP41 air quality sensor is a digital gas-sensing solution designed to monitor indoor air pollution by detecting volatile organic compounds (VOCs) and nitrogen oxides (NOx). Developed by Sensirion, it combines advanced MOx sensing technology, temperature-controlled micro hotplates, and a digital I2C interface in a compact package. With its excellent long-term stability, low power consumption, and reliable gas detection, the SGP41 is widely suited for air purifiers, ventilation systems, HVAC equipment, and smart home applications. In this article, we will explore the SGP41 pinout, specifications, key features, working principles, applications, and GY-SGP41 sensor module to help you better understand this air quality sensing solution.
1. What is SGP41 Air Quality Sensor?
6. GY-SGP41 Air Quality Gas Sensor Module

The SGP 41 is a digital air quality sensor developed by Sensirion for monitoring volatile organic compounds (VOCs) and nitrogen oxides (NOx) in indoor environments. It is designed for easy integration into air purifiers, demand-controlled ventilation systems, and other air treatment equipment.
Based on Sensirion's CMOSens® technology, the SGP41 integrates metal-oxide (MOx) gas sensing elements, temperature-controlled micro hotplates, and a digital I2C interface into a single compact chip. It provides separate VOC and NOx signals that can process by Sensirion's Gas Index Algorithm to evaluate indoor air quality and support automatic ventilation or air purification control.
The sensor offers excellent resistance to contaminating gases commonly found in real-world environments. Its robust sensing elements and gas index processing provide outstanding long-term stability, low signal drift, and reliable performance.
With a compact 2.44 × 2.44 × 0.85 mm DFN package, the SGP 41 is suitable for space-constrained electronic designs. Its tape-and-reel packaging and compatibility with standard surface-mount technology (SMT) assembly also make it suitable for high-volume manufacturing.
The following table summarizes the main electrical and operating specifications of the SGP41 air quality sensor.
Parameter | Value |
Manufacturer | Sensirion AG |
Series | SGP41 |
Category | Sensors, Transducers |
Product Type | Gas Sensor / Air Quality Sensor |
Packaging | Tape & Reel (TR) |
Output Interface | I2C |
Supply Voltage | 1.7V~3.6V |
Supply Current | 3mA |
Operating Temperature | -10°C~50°C |
Package | 6-pin DFN |
Package Dimensions | 2.44 × 2.44 × 0.85 mm |
The SGP 41 comes in a compact 6-pin DFN package. Its pins provide power connections, I2C communication, and hotplate supply functions. Understanding the pin configuration is important when designing a PCB or connecting the sensor to a microcontroller.

Pin | Name | Description |
1 | VDD | Main supply voltage |
2 | VSS | Ground connection |
3 | SDA | Bidirectional I2C serial data |
4 | N/A | No electrical function; connect to ground |
5 | VDDH | Supply voltage for the hotplate |
6 | SCL | Bidirectional I2C serial clock |
Pinout Notes:
VDD and VSS: Provide the main power supply and ground reference for the sensor.
SDA and SCL: Form the I2C communication interface used to exchange measurement commands and data with a microcontroller.
VDDH: Supplies the internal gas-sensing hotplate.
Pin 4: Has no electrical function and should connect to ground as specified by the manufacturer.

The SGP 41 combines compact packaging, digital communication, and reliable gas-sensing performance for indoor air quality applications.
Dual VOC and NOx sensing: The sensor detects two important categories of indoor air pollutants: volatile organic compounds and nitrogen oxides. Its separate sensing signals provide useful information for monitoring changing indoor air conditions.
Excellent long-term stability: The MOx sensing elements are designed to resist contaminating gases commonly encountered in real-world environments. This provides reliable operation, low drift, and extended sensor lifetime.
Digital I2C interface: The sensor communicates through an I2C interface, making it easy to connect with microcontrollers and embedded control systems.
Compact DFN package: The 2.44 × 2.44 × 0.85 mm six-pin DFN package supports space-saving PCB designs and compact electronic products.
Low power consumption: With a typical supply current of approximately 3mA at 3.3V, the SGP41 is suitable for applications requiring continuous indoor air quality monitoring.
High-volume manufacturing compatibility: Tape-and-reel packaging and reflow soldering compatibility allow the sensor to integrate into automated SMT production processes.
The SGP 41 is designed for continuous indoor air quality monitoring and automatic control of air treatment equipment. Its VOC and NOx sensing capabilities make it suitable for applications where indoor pollution levels need to detect and manage.
Common applications include:
Air Purifiers: Detect VOC and NOx changes and automatically adjust purification levels according to indoor air quality.
Demand-Controlled Ventilation: Monitor indoor pollutants and regulate fresh-air ventilation based on measured conditions.
Smart HVAC Systems: Provide air quality information for intelligent heating, ventilation, and air conditioning control.
Indoor Air Quality Monitors: Measure changes in VOC and NOx levels in homes, offices, schools, and commercial buildings.
Smart Home Devices: Support automated environmental monitoring and air treatment systems.
Automotive Cabin Air Monitoring: Monitor air quality inside vehicle cabins and support automatic ventilation control.
Residential and Commercial Buildings: Help maintain indoor environmental quality through continuous pollutant monitoring.
By combining VOC and NOx measurements with the Gas Index Algorithm, the SGP41 enables air treatment equipment to respond automatically to changing indoor conditions.

The GY-SGP41 air quality gas sensor module is a sensor breakout solution based on the Sensirion SGP 41. It is designed to detect volatile organic compounds (VOC) and nitrogen oxides (NOx), making it suitable for indoor air quality monitoring and automatic air treatment applications.
The module uses Sensirion's gas sensing technology and Gas Index Algorithm to process the sensor signals into meaningful air quality information. Can use these signals by an external microcontroller or control system to trigger air purifiers, ventilation equipment, and other air treatment devices without requiring manual operation.
For example, when VOC or NOx levels increase, an air purifier can automatically increase its operating level. Once the pollution level returns to an acceptable condition, the system can reduce its operation or switch to a lower-power mode. This automatic control helps improve indoor air quality while reducing unnecessary energy consumption.
The SGP41's multi-pixel MOx sensing technology also provides strong resistance to contaminating gases, supporting reliable measurements, long-term stability, and low drift in everyday environments.
GY-SGP41 Module Specifications
Parameter | Value |
Sensor Chip | SGP 41 |
Sensor Output | Digital 16-bit raw signal |
Processed Output | 0~500 VOC Index |
VOC Measurement Range (TVOC) | 0~1000 ppm |
TVOC Device-to-Device Variation | ±15% m.v. |
Response Time | Less than 10 seconds |
Startup Time | 1 hour |
Supply Voltage | 3.3V~5V (module specification) |
Average Supply Current | 3mA |
Maximum Supply Current | 3.4mA |
Detection Limit | Less than 0.05 ppm ethanol equivalent or less than 10% of the concentration setpoint, whichever is greater |
How Does the GY-SGP41 Module Work?
The GY-SGP41 module uses the following process to monitor indoor air quality:
1. Gas Detection: The MOx sensing elements detect changes in VOC and NOx concentrations in the surrounding air.
2. Signal Output: The sensor generates digital raw measurement signals and communicates with the external controller through I2C.
3. Algorithm Processing: Sensirion's Gas Index Algorithm processes the raw signals to generate VOC and NOx indices.
4. Automatic Control: A connected microcontroller uses the processed information to control air purifiers, ventilation systems, or other air treatment equipment.
This approach allows air treatment devices to respond automatically to indoor pollution without requiring continuous manual adjustment.
The SGP 41 measures indoor air quality by detecting volatile organic compounds (VOCs) and nitrogen oxides (NOx). It uses metal-oxide sensing elements to generate separate digital signals for these gas categories. Can process these signals using Sensirion's Gas Index Algorithm to evaluate changes in indoor air quality.
The SGP 41 uses an I2C digital communication interface. It provides SDA for bidirectional data transmission and SCL for the serial clock signal. This interface allows the sensor to communicate with microcontrollers and embedded systems, making integration into air monitoring and automatic ventilation equipment straightforward.
The bare SGP 41 sensor operates with a supply voltage between 1.7V and 3.6V. A typical operating voltage is 3.3V. Some breakout modules support a wider input voltage, such as 3.3V~5V, depending on their onboard power circuitry. Always verify the module specifications before connecting it.
The SGP40 is designed primarily for VOC-based indoor air quality monitoring, while the SGP41 detects both VOCs and NOx. This additional NOx sensing capability makes the SGP41 suitable for applications requiring more comprehensive indoor air quality information and more advanced automatic air treatment control.
The GY-SGP41 module specifications indicate a startup time of approximately one hour. This warm-up period allows the sensing elements to stabilize before measurements are used for reliable air quality evaluation. Should also operate the sensor according to Sensirion's recommended initialization and measurement procedures.
Yes. The SGP 41 can be integrated with Arduino-compatible microcontrollers through its I2C interface. The controller communicates with the sensor, retrieves raw VOC and NOx measurement signals, and processes them using the appropriate Gas Index Algorithm. A compatible library can simplify initialization, measurement, and data processing.
Yes. The SGP 41 can provide VOC and NOx information for automatic air purifier control. A connected microcontroller processes the sensor readings and adjusts the purifier's operating speed according to indoor air quality. This allows the purifier to respond to pollution changes and reduce unnecessary operation when air quality improves.
The SGP 41 uses a compact six-pin DFN package measuring 2.44 × 2.44 × 0.85 mm. Its small dimensions make it suitable for compact electronic products, air quality monitoring devices, smart home equipment, and other applications where PCB space is limited.
The SGP41 is a compact digital air quality sensor that combines VOC and NOx detection with Sensirion's CMOSens® technology. Its I2C interface, low power consumption, excellent long-term stability, and small DFN package make it a practical solution for continuous indoor air quality monitoring.
With the support of Sensirion's Gas Index Algorithm, the sensor can provide useful air quality information for automatic air purifiers, ventilation systems, HVAC equipment, and smart home devices. Whether used as a standalone sensing component or integrated into a GY-SGP41 module, the SGP41 offers a reliable solution for developing intelligent indoor air quality monitoring and control systems.
1. SGP40 Air Quality Sensor: Pinout, Specifications, Features
2. SGP30 Air Quality Sensor: Guide, and CCS811 Comparison
3. LCD1602 Display Module 1602A 16X2 Compatible with Arduino R3 Mega2560 Raspberry Pi
2026-01-23
2025-06-30
2025-12-14
2025-05-29
2026-03-26
2025-09-04
2025-05-06
2025-09-05
2026-02-11
2025-07-28